Settings specific to the CVX-1468
DIP Switch settings for the 1368 functions have changed
Old 1368 Setting (if exists) / New 1468 Setting
Setting #120
Wiegand HID40 to WPS serial
Input Wiegand 40b: XXXXFFFFFFFFFFFFBBBBBBBBBBBBBBBBXXXXXXXX
12b FC, 16b Badge
Output Serial: <STX>000000FFFFFBBBBB<ETX>
Setting #1 / Setting #121
Wiegand 33b to WPS serial
Wiegand Input = PFFFFFFFBBBBBBBBBBBBBBBBBBBBBBBBP
Serial Output = <STX>0000000FBBBBBBBB<ETX>
Facility code is decoded as 3 digit number, only last (rightmost) digit is placed into output
stream
Setting #35 / Setting #122
Same function as the CVX-1399 DIP Switch #3 ON (CVX-1399B)
Setting #86 / Setting #124 26 bit Wiegand output
Processes Transcore tags using Generic process
Processes Transcore 26 bit ASCII tags
Setting #87 / Setting #125
Processes Transcore 26 bit ASCII tags, but generates 34 bit Cardkey output.
Setting #88 / Setting #126 37 bit Wiegand output
Processes Transcore tags using Generic process
Processes Transcore 26 bit ASCII tags
CVX-1468 Function QuickReference