ENTRACOMP® 26SA With Remote Open InputUser/Installation Manual
Example: Validate card number 100. Place the “1” card on the TOUCH CARD® reader plate, remove it and place the “0” card on the TOUC
VOIDING CARDS. Cards may also be voided (cancelled) either singly or in blocks. Follow the instructions for validating above, replacing the “VALID”
DOOR UNLOCK MODE. The relay may be set to stay latched (door unlocked) during periods when access control is unwanted. While in the “DOOR UNLOCK” mo
To deactivate the Timed Antipassback feature, place the “0” card on the TOUCH CARD® reader plate and remove it. Then place the “*” card on the TOUCH C
Secura Key • 10RELAY CONFIGURATION. The solid-state relay can be set to be Normally Closed, Normally Open or to operate with the SecuRelayTM for incr
INSTALLATIONWIRING INSTRUCTIONSThe ENTRACOMP® 26SA is provided with a connector and 7 wire leads (See Figure 1). Using appropriate wire nuts or crimp
Secura Key • 122%02/'2!-2%,!9&/2.#&/2-!'.%4)#,/#+3&)'52%
Secura Key • 132%-!).).'2%!$%27)2%3./453%$3%%4!",%&/27)2).'&)'52%
REMOTE OPEN (REX). Connect the Brown and orange wires to any Normally Open switch. Closing this circuit will activate the Latch Relay for the number
Secura Key • 15INSTALLATION INSTRUCTIONSSURFACE HOUSING TO SINGLE GANG ELECTRICAL BOX(See Figure 4)1. For exterior walls, apply 1/4 inch bead of sili
COPYRIGHT © 2007SOUNDCRAFT INC.
Secura Key • 162. Mount plate to wall using appropriate fasteners. Use at least four of six holes provided.3. Connect power and control lines to wi
Secura Key • 174. Connect power and control lines to wire leads provided as per the wiring instructions.5. Plug connector into reader board.6. Place
FIGURE 4FIGURE 5Secura Key • 18
FIGURE 6FIGURE 7Secura Key • 19
Secura Key • 20FLUSH MOUNT TO EXISTING 5S BOX (See Figure 8)1. Use wall cutout template provided. Align template over 5S box. (When running wires t
Secura Key • 21FLUSH MOUNT WITH 5S BOX (See Figure 9)1. Use the wall cutout template provided. Locate template on the wall. Transfer appropriate cu
Secura Key • 228. Place reader and faceplate assembly against the mounting plate. Faceplate will hook onto mounting plate by pushing plate in and the
Secura Key • 236. Be sure all appropriate wiring has been connected to the terminal board and then plug the terminal board cable into the socket on t
FIGURE 9FIGURE 10Secura Key • 24
METAL SURFACE HOUSING TO SINGLE GANG ELECTRICAL BOX (Figure 11)1. For exterior walls, apply 1/4 inch bead of silicone sealant around rear perimeter
TABLE OF CONTENTSINTRODUCTION ... 1SETTING THE SYSTEM (FACILITY) CODE ...
Secura Key • 262. Mount plate to wall using appropriate fasteners. Use at least four of six holes provided.3. Connect power and control lines to wi
4. Connect power and control lines to wire leads provided as per the wiring instructions.5. Plug connector into reader board.6. Place ENTRACOMP® 26S
FIGURE 11FIGURE 12Secura Key • 28
FIGURE 13FIGURE 14Secura Key • 29
SPECIFICATIONSPHYSICAL Surface Housing Flush Housing Metal HousingDepth 2.25 in (5.72 cm) 1.50 in (3.8 cm) 1.75 in (4.
WARRANTY (U.S. and Canadian)“Secura Key products are warranted against defects in materials and workmanship for a period of 2 years from the date of p
20301 Nordhoff StreetChatsworth, CA 91311Phone: 818-882-0020 • Fax: 818-882-7052TOLL FREE (800) [email protected]
FLUSH MOUNT TO EXISTING 5S BOX ... 20FLUSH MOUNT WITH 5S BOX ... 21FLUSH MOUNT WITHOUT 5S BOX ...
INTRODUCTIONThe ENTRACOMP® 26SA is a stand alone access control system that will control access to a passageway for up to 65,503 individuals. There ar
Secura Key • 2 “0” ZERO “1” ONE “2” TWO “3”
SETTING THE SYSTEM (FACILITY) CODE When received, the correct system code may already be set. Should it become necessary to reset the system code, re
FIGURE 1Secura Key • 4
PROGRAMMING THE ENTRACOMP® 26SAFunctions of the ENTRACOMP® 26SA are programmed by placing the program cards on the TOUCH CARD® reader plate in a prop