FAAC International, Inc.
303 Lexington Avenue
Cheyenne, WY 82007
www.faacusa.com
February, 2009
400 Operator And
455 D Control Panel
Installation Manual
CONTENTS
Important Safety Information 2
Technical Data 4
Unpacking the Operator 5
The 400 Compact Operator General Characteristics 6
Installation Instructions 6
Prepare the Gate 6
Manual Release Mechanism 7
Install the Operator 7
Install the 455 D Control Panel 10
Exploded View, 400 CBAC 12
400 Parts List 13
The 455 D Control Panel General Description 14
Installing the 455 D Control Panel 14
Connect the Main Power Supply 14
Connect the Operator to the Control Panel 15
Check the Motor’s Direction of Rotation 15
Connect Other Devices 16
Set Other Operating Controls 18
Programming 20
Learning of Operating Times 22
Learning of Normal Times 22
Learning Times with Gatecoder 22
Automated Systems Test 23
Logic Tables of 455 D Control Panel 24
Maintenance 26
Safety in Gate Design 26
Troubleshooting 27
Limited Warranty 28
T HE 400 OPERATOR AND
455 D C
ONTROL PANEL:
I
NSTALLATION MANUAL
The 455 D Control Panel
Installation Instructions
Vue de la page 0
1 2 3 4 5 6 ... 27 28

Résumé du contenu

Page 1 - CONTENTS

FAAC International, Inc. 303 Lexington Avenue Cheyenne, WY 82007 www.faacusa.com February, 2009 400 Operator And 455 D Control Panel Installation Ma

Page 2 - IMPORTANT SAFETY INFORMATION

Page 10 February, 2009 400 Operator And 455 D Control Panel Installation Manual BLEED THE OPERATOR Air in the hydraulic fluid causes erratic perfor

Page 3 - U.L. CLASS AND FAAC OPERATOR

Page 11 February, 2009 400 Operator And 455 D Control Panel Installation Manual POS PART # DESCRIPTION QTY 1 7049005 Retainer (Brass) 4 2 N/A O

Page 4 - TECHNICAL DATA

Page 12 February, 2009 400 Operator And 455 D Control Panel Installation Manual EXPLODED VIEW, 400 CBAC POS PART # DESCRIPTION QTY 1 7171485 Flange

Page 5 - UNPACKING THE OPERATOR

Page 13 February, 2009 400 Operator And 455 D Control Panel Installation Manual 400 PARTS LIST POS PART # DESCRIPTION QTY 1 2036 Galvanized Nut (8

Page 6 - INSTALLATION INSTRUCTIONS

THE 455 D CONTROL PANEL GENERAL DESCRIPTION The FAAC 455 D control panel is used to operate the following models. Swing gate operators: 400 412

Page 7 - TTACH THE REAR MOUNTING

RADIO1-455D115 = 115V1-455D = 230VF2F1MMK+OP -CL+24 VFS WNC -B -STOPA + TXFS WW. L.LOCK9 10 11 12 13 14 15 16 17 18 1922 23 24 25LAMPCOMOP CLMOTOR 1MO

Page 8 - TO THE OPERATOR

Page 16 February, 2009 400 Operator And 455 D Control Panel Installation Manual NOTE : In order to comply with UL 325, two setsof FAAC photobeams mu

Page 9 - ATTACH THE OPERATOR TO THE

Page 17 February, 2009 400 Operator And 455 D Control Panel Installation Manual ACTIVATING DEVICES AND RADIO RECEIVER: The activating devices and r

Page 10 - EXPLODED VIEW, LOCKING CAP

command to open and a command to close. A second command during opening stops the gate. A second command during closing reopens the gate. • EP (se

Page 11 - EXPLODED VIEW, CYLINDER

Page 19 February, 2009 400 Operator And 455 D Control Panel Installation Manual Figure 13. Pre-wired Enclosure with the 455 D Control Panel T

Page 12 - EXPLODED VIEW, 400 CBAC

Both the installer and the owner and/or operator of this system need to read and understand this installation manual and the safety instructions suppl

Page 13

Page 20 February, 2009 400 Operator And 455 D Control Panel Installation Manual PROGRAMMING To program the automated system, the “Programming Mode”

Page 14 - THE 455 D CONTROL PANEL

Page 21 February, 2009 400 Operator And 455 D Control Panel Installation Manual THE 455 D CONTROL PANEL INSTALLATION INSTRUCTIONS FAIL SAFE: If thi

Page 15 - OTATION

Page 22 February, 2009 400 Operator And 455 D Control Panel Installation Manual can be commanded by the OPEN A (by push-button wired to terminals “O

Page 16 - CONNECT OTHER DEVICES

Page 23 February, 2009 400 Operator And 455 D Control Panel Installation Manual flashing. The procedure has ended and the gate is ready to operate,

Page 17

Page 24 February, 2009 400 Operator And 455 D Control Panel Installation Manual THE 455 D CONTROL PANEL INSTALLATION INSTRUCTIONS A (Automatic) Logi

Page 18 - ET OTHER OPERATING CONTROLS

Page 25 February, 2009 400 Operator And 455 D Control Panel Installation Manual THE 455 D CONTROL PANEL INSTALLATION INSTRUCTIONS E (Semi-automatic)

Page 19 - 400 Operator And

THE 400 OPERATOR The FAAC recommended maintenance schedule varies according to the frequency of use of the operators, whether lightly used operators

Page 20 - PROGRAM BUTTONS

PROBLEM: THE GATE DOES NOT RESPOND TO AN ACTIVATING SIGNAL. SOLUTION: You should have at least one operator wired to terminals 1,2 and 3. Be sure th

Page 21 - ADVANCED PROGRAMMING

Page 28 February, 2009 400 Operator And 455 D Control Panel Installation Manual To the original purchaser only: FAAC International, Inc., warrants,

Page 22 - LEARNING OF NORMAL TIMES

February, 2009 400 Operator And 455 D Control Panel Installation Manual Model Duty Cycle Typical Use Class I: Residential Vehicular Gate Operator

Page 23 - AUTOMATED SYSTEM TEST

Page 4 February, 2009 400 Operator And 455 D Control Panel Installation Manual TECHNICAL DATA 1 The operator requires external locks. 2 Locks in

Page 24 - S (Security) Logic (455 D)

Page 5 February, 2009 400 Operator And 455 D Control Panel Installation Manual UNPACKING THE OPERATOR When you receive your 400 Operator, complete t

Page 25

THE 400 OPERATOR GENERAL CHARACTERISTICS The FAAC 400 Operator is an automatic gate operator for a swinging gate leaf. It can accommodate a gate lea

Page 26 - MAINTENANCE

Page 7 February, 2009 400 Operator And 455 D Control Panel Installation Manual MANUAL RELEASE MECHANISM To move the gate operator manually during i

Page 27 - TROUBLESHOOTING

Page 8 February, 2009 400 Operator And 455 D Control Panel Installation Manual ATTACH THE MOUNTING HARDWARE Insert the rear fork (hex cut up if you

Page 28 - LIMITED WARRANTY

Page 9 February, 2009 400 Operator And 455 D Control Panel Installation Manual Figure 5. Important mounting dimensions for outward swing 400 ope