212iLW/242iLW Standalone Keypad
Installation/Programming Manual
Document # 6050700, Rev. 1.1, D2d
12
5.6 Wiring an Accessory Relay Board
(242 Only)
The accessory relay board contains physical outputs 2, 3, and 4
shown in the table below.
Physical Output Relay Connector
2 K2 P1
3 K3 P2
4 K4 P3
Use the wire harnesses supplied with the relay board to connect to
the relays. The wire colors are shown in the table below.
Wire Color Relay Connection
Gray Normally Closed
Blue Common
Green Normally Open
5.7 Wiring an Integrated Access Control System Using
the Accessory Relay Board
Physical outputs 2, 3, and 4 are defaulted to the alarm shunt, propped
door, and forced door virtual outputs, respectively. Use the following
steps to wire the alarm shunt, propped door alarm, and forced door
alarm.
Figure 9 Wiring the Accessory Relay Board